
Extensions
Permitted development rear extensions
Most houses can be extended at the back by one storey without a planning application: 3 metres for a terrace or semi, 4 metres if detached. Through a 42 day prior approval process, those figures become 6 and 8 metres. The detail is in the limits, and older houses with back additions are where most mistakes happen.
The law: GPDO 2015, Schedule 2, Part 1, Class A as amended (including A.1, A.2, A.3 and A.4); householder technical guidance. Sources last reviewed in November 2026.
In this guide
The limits at a glance
| Limit | Terrace or semi | Detached | Rule |
|---|---|---|---|
| Single storey depth, standard | 3 m | 4 m | A.1(f)(i) |
| Single storey depth, with prior approval | 6 m | 8 m | A.1(g) |
| Single storey height | 4 m maximum | A.1(f)(ii) | |
| More than one storey: depth | 3 m | A.1(h)(i) | |
| More than one storey: rear boundary | At least 7 m from the boundary opposite the rear wall | A.1(h)(ii) | |
| Eaves close to a boundary (2 m or less) | Not above 3 m | A.1(i) | |
| Eaves and ridge | Eaves no higher than existing eaves; nothing higher than existing roof | A.1(d), (e) | |
| Garden coverage | All buildings other than the original house no more than half the curtilage | A.1(b) | |
| Materials | Similar in appearance to the existing house (not conservatories) | A.3(a) | |
None of these rights apply to flats or maisonettes, to houses created by certain permitted changes of use, or where an earlier permission has removed them by condition. In a conservation area, more limits apply: see the section on designated land below and the separate guide on permitted development in a conservation area.
Measuring from the original rear wall
All depths are measured from the rear wall of the original house. "Original" means as it was first built, or as it stood on 1 July 1948 if it was built before then. For a Victorian or Georgian house, that means anything added after 1948, such as a 1970s kitchen extension, is not part of the original house and counts towards the allowance.
Victorian terraces raise a particular question: the two-storey back addition (the "outrigger" or "closet wing") that most of them have. If it went up at the same time as the house, it is part of the original house. The rear wall of the original house then has two parts: the end wall of the back addition and the rear wall of the main house beside it, at the head of the side return. The technical guidance treats each rear wall separately, so an extension off the end of the back addition is measured from that end wall.
The trap is the side return. Infilling the side return means building alongside the back addition, beyond the side wall of that addition. Under A.1(j), anything built out past a side wall is limited to one storey, a height of 4 m and a width of half the original house. A side return infill that also extends beyond the rear wall becomes a wrap-around, and the A.1(ja) rule makes clear that the new part and any existing extension it joins are tested together against every relevant limit, not split into parts. Many side return schemes on terraces fail on width or on eaves near the boundary. On designated land they fail outright.

Height and the 2 m boundary rule
For a single storey rear extension, the maximum height is 4 m. If any part is within 2 m of a boundary, the eaves of that part cannot exceed 3 m. On a terrace, the extension will almost always sit within 2 m of the party boundary, so the 3 m eaves limit is usually the one that shapes the design.
Heights are measured from ground level immediately next to the wall, on the side where the ground is highest if it slopes. For a flat roof, the eaves height is the top of the wall, not counting a parapet. A flat-roofed extension at 3 m with a 200 mm parapet is acceptable; one with its roof deck at 3.3 m is not.
A pitched or lean-to roof can rise to 4 m at its highest point, provided the eaves stay at or below 3 m within 2 m of the boundary. This is why so many terrace extensions have a mono-pitch roof rising away from the neighbour.
The larger home extension route
For single storey rear extensions between 3 and 6 m on a terrace or semi, or between 4 and 8 m on a detached house, you can use the prior approval procedure in paragraph A.4. It is not available on designated land (conservation areas, National Parks, National Landscapes, the Broads, World Heritage Sites) or on a Site of Special Scientific Interest.
- Notify the council. Send a written description, a plan showing the site and the dimensions (depth, maximum height, eaves height), the addresses of all adjoining premises, your contact details and the fee of £249 (from 1 April 2026).
- Council notifies neighbours. It serves notice on adjoining owners or occupiers, giving at least 21 days to object, not counting public holidays.
- Amenity assessment. If an adjoining neighbour objects, the council considers the impact on the amenity of adjoining premises only: light, outlook, privacy. It does not reassess design in general.
- Decision. You may build once you have written notice that prior approval is not required or is given, or once 42 days have passed from receipt without a decision.
- Build what you described. Under A.4(11) the work must follow the approved details, or the information you submitted if the 42 days passed without a decision, unless the council agrees otherwise in writing.
Count the 42 days from the date the council receives the notification, not the date it registers it. Keep proof of the submission date. Councils that miss the deadline cannot later refuse.
Two storey rear extensions
An extension of more than one storey may extend no more than 3 m beyond the rear wall and must be at least 7 m from the boundary of the curtilage opposite that wall. On a typical London terrace with a 10 m garden, the 7 m rule usually allows only a modest extension, and the 2 m boundary rule often stops it anyway, because a two-storey extension's eaves will be well above 3 m.
Upper floor windows in side elevations must be obscure glazed and non-opening below 1.7 m above the floor. The roof pitch should match the main house as far as practicable. Two storey rear extensions are not permitted development on designated land at all.
Worked examples on older houses
Mid-terrace, back addition, not in a conservation area
A Victorian mid-terrace with an original two-storey back addition. The owner wants a single storey extension off the end of the back addition, 3 m deep, full width of the back addition, flat roof at 3 m. Measured from the end wall of the back addition, depth is 3 m: within the limit. Eaves at 3 m within 2 m of the boundary: within the limit. Permitted development, and a lawful development certificate is recommended.
Same house, 5 m deep
Depth now 5 m. Over 3 m, under 6 m, not in a conservation area: the larger home extension route applies. Fee £249, 42 days. If the neighbour objects, the council will look at the loss of light to their rear window. Alternatively, a householder planning application at £548 gives a full permission that can be varied later.
Side return infill, house in a conservation area
A side return infill extends beyond the side wall of the back addition. In a conservation area, A.2(b) prohibits any extension beyond a side wall. Planning permission is needed. Most councils will grant a well-designed infill on a rear elevation, but expect conditions on materials.
Semi with a 1990s conservatory
The conservatory projects 2.5 m from the original rear wall. The owner wants to replace it with a 3.5 m brick extension. The new extension is measured from the original rear wall, so 3.5 m exceeds the 3 m limit; prior approval is needed outside designated land. If the conservatory stayed and a new 3 m extension were built beside it, both together would have to be assessed against the limits.
Other conditions that are easy to miss
- Materials. They must be of similar appearance to the existing house. A fully rendered extension on a stock brick terrace, or one clad in timber, may not qualify. Large areas of glazing in a framed extension are generally accepted; conservatories are exempt from the materials condition.
- Balconies and raised platforms. A verandah, balcony or raised platform is excluded. A raised terrace more than 0.3 m high is not permitted under Class A and needs separate consideration.
- Listed buildings. Permitted development rights for extensions still technically apply to a listed house, but listed building consent will be needed for the same work and judged on heritage merit.
- Building regulations and party walls. Building regulations approval applies to practically any extension, and work on or near the party wall triggers notices under the Party Wall etc. Act 1996.
Questions readers ask
- How far can I extend at the back without planning permission?
- One storey, up to 4 m high, reaching 3 m from the original rear wall of a terrace or semi and 4 m from a detached house. Prior approval stretches that to 6 m and 8 m, except in conservation areas and on other designated land.
- Does a side return extension count as permitted development?
- It can be, away from designated land, provided it stays one storey, keeps under 4 m in height, takes up no more than half the house's original width and passes the other tests. In a conservation area it never is.
- Do I need to tell the council about a 3 m extension?
- No, unless you are using the prior approval route. A lawful development certificate is optional but recommended.
- Can I build a two storey extension under permitted development?
- Only up to 3 m deep, at least 7 m from the rear boundary, and not on designated land. On most terraces the boundary rules rule it out.
Where we checked
- Householder permitted development: the government's technical guidance, gov.uk
- GPDO 2015, Schedule 2, Part 1, legislation.gov.uk
- Extensions, Planning Portal
Not sure which of these applies to you? Answer seven questions and see which consents your project needs.